<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">sibmed</journal-id><journal-title-group><journal-title xml:lang="ru">Сибирский научный медицинский журнал</journal-title><trans-title-group xml:lang="en"><trans-title>Сибирский научный медицинский журнал</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">2410-2512</issn><issn pub-type="epub">2410-2520</issn><publisher><publisher-name>ИЦиГ СО РАН</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.15372/SSMJ20200603</article-id><article-id custom-type="elpub" pub-id-type="custom">sibmed-516</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>ОБЗОРЫ</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>REVIEWS</subject></subj-group></article-categories><title-group><article-title>Становление инвазивной ЭЭГ в хирургии эпилепсии (обзор литературы)</article-title><trans-title-group xml:lang="en"><trans-title>Development of invasive EEG in epilepsy surgery (review)</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0002-5337-8715</contrib-id><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Джафаров</surname><given-names>В. М.</given-names></name><name name-style="western" xml:lang="en"><surname>Dzhafarov</surname><given-names>V. M.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Виджай Маисович Джафаров</p><p>630087, Новосибирск, ул. Немировича-Данченко, 132/1</p></bio><bio xml:lang="en"><p>Vidzhai M. Dzhafarov</p><p>630087, Novosibirsk, Nemirovicha-Danchenko str., 132/1</p></bio><email xlink:type="simple">mvijayd@hotmail.com</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0002-1209-8960</contrib-id><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Рзаев</surname><given-names>Д. А.</given-names></name><name name-style="western" xml:lang="en"><surname>Rzaev</surname><given-names>J. A.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Джамиль Афетович Рзаев - доктор медицинских наук</p><p>630087, Новосибирск, ул. Немировича-Данченко, 132/1</p></bio><bio xml:lang="en"><p>Jamil A. Rzaev -doctor of medical science.</p><p>630087, Novosibirsk, Nemirovicha-Danchenko str., 132/1</p></bio><email xlink:type="simple">jamilrzaev@gmail.com</email><xref ref-type="aff" rid="aff-1"/></contrib></contrib-group><aff-alternatives id="aff-1"><aff xml:lang="ru"><institution>Федеральный центр нейрохирургии Минздрава РФ</institution><country>Россия</country></aff><aff xml:lang="en"><institution>Novosibirsk Center of Neurosurgery of Minzdrav of Russia</institution><country>Russian Federation</country></aff></aff-alternatives><pub-date pub-type="collection"><year>2020</year></pub-date><pub-date pub-type="epub"><day>26</day><month>12</month><year>2020</year></pub-date><volume>40</volume><issue>6</issue><fpage>23</fpage><lpage>33</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Джафаров В.М., Рзаев Д.А., 2020</copyright-statement><copyright-year>2020</copyright-year><copyright-holder xml:lang="ru">Джафаров В.М., Рзаев Д.А.</copyright-holder><copyright-holder xml:lang="en">Dzhafarov V.M., Rzaev J.A.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://sibmed.elpub.ru/jour/article/view/516">https://sibmed.elpub.ru/jour/article/view/516</self-uri><abstract><p>Для определения объема хирургического вмешательства при медикаментозно-резистентной эпилепсии используются методы диагностики, направленные на поиск зоны начала эпилептических приступов. Среди всех методов диагностики «золотым стандартом» в определении эпилептогенной зоны является инвазивный ЭЭГ-ви-деомониторинг, к настоящему моменту имеющий богатую историю применения. В данной статье приведена историческая справка об инвазивной записи ЭЭГ с обзором литературы, касающимся техник проведения, анализа их преимуществ и недостатков, актуальных вопросов на сегодняшний день.</p></abstract><trans-abstract xml:lang="en"><p>There are different diagnostic methods that used for localization of the seizure onset zone in focal refractory epilepsy cases. Invasive video-EEG recording is the «gold standard» in determining the epileptogenic zone among other diagnostic methods. Invasive EEG already has a long history of using. This article provides historical review and analysis of the techniques, their advantages and disadvantages, current issues.</p></trans-abstract><kwd-group xml:lang="ru"><kwd>эпилепсия</kwd><kwd>ЭЭГ</kwd><kwd>инвазивный ЭЭГ-видеомониторинг</kwd><kwd>стерео-ЭЭГ</kwd><kwd>субдуральный ЭЭГ-мониторинг</kwd></kwd-group><kwd-group xml:lang="en"><kwd>epilepsy</kwd><kwd>EEG</kwd><kwd>invasive video-EEG monitoring</kwd><kwd>stereo-EEG</kwd><kwd>subdural EEG monitoring</kwd></kwd-group><funding-group><funding-statement xml:lang="ru">Авторы благодарят Г.И. Мойсак за критический анализ выполненной работы</funding-statement><funding-statement xml:lang="en">Authors would like to thank G.I. Moysak for critical review of this manuscript</funding-statement></funding-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Крылов В.В., Гехт А.Б., Трифонов И.С., Лебедева А.В., Каймовский И.Л., Синкин М.В., Григорьева Е.В., Гришкина М.Н., Шишкина Л.В., Кочеткова О.О. Исходы хирургического лечения пациентов с фармакорезистентными формами эпилепсии. Журн. неврологии и психиатрии. 2016; 116 (9): 13-18. doi:10.17116/jnevro20161169213-18</mixed-citation><mixed-citation xml:lang="en">Krylov V.V., Guekht A.B., Trifonov I.S., Lebedeva A.V., Kaimovsky I.L., Sinkin M.V., Grigorieva E.V., Grishkina M.N., Shyshkina L.V., Kochetkova O.O. Outcomes of surgical treatment of patients with phar-macoresistant epilepsy. Zhurnal nevrologii i psikhi-atrii imeni Sergeya Sergeevicha Korsakova = S.S. Korsakov Journal of Neurology and Psychiatry. 2016; 116 (9): 13-18. [In Russian]. doi:10.17116/jnevro20161169213-18</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Banerjee P., Filippi D., Hauser W.A. The descriptive epidemiology of epilepsy - A review. Epilepsy Res. 2009; 85 (1): 31-45. doi:10.1016/j.eplep-syres.2009.03.003</mixed-citation><mixed-citation xml:lang="en">Banerjee P., Filippi D., Hauser W.A. The descriptive epidemiology of epilepsy - A review. Epilepsy Res. 2009; 85 (1): 31-45. doi:10.1016/j.eplep-syres.2009.03.003</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Jin P., Wu D., Li X., Ren L., Wang Y. Towards precision medicine in epilepsy surgery. Ann. Transl. Med. 2016; 4 (2): 24. doi: 10.3978/j.issn.2305-5839.2015.12.65</mixed-citation><mixed-citation xml:lang="en">Jin P., Wu D., Li X., Ren L., Wang Y. Towards precision medicine in epilepsy surgery. Ann. Transl. Med. 2016; 4 (2): 24. doi: 10.3978/j.issn.2305-5839.2015.12.65</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Jayakar P., Gotman J., Harvey A., Palmini A., Tassi L., Schomer D., Dubeau F., Bartolomei F., Yu A., Krsek P, Velis D., Kahane P. Diagnostic utility of invasive EEG for epilepsy surgery: Indications, modalities, and techniques. Epilepsia. 2016; 57 (11): 1735-1747. doi: 10.1111/epi.13515</mixed-citation><mixed-citation xml:lang="en">Jayakar P., Gotman J., Harvey A., Palmini A., Tassi L., Schomer D., Dubeau F., Bartolomei F., Yu A., Krsek P, Velis D., Kahane P. Diagnostic utility of invasive EEG for epilepsy surgery: Indications, modalities, and techniques. Epilepsia. 2016; 57 (11): 1735-1747. doi: 10.1111/epi.13515</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Taussig D., Montavont A., Isnard J. Invasive EEG explorations. Neurophysiol. Clin. 2015; 45 (1): 113-119. doi:10.1016/j.neucli.2014.11.006</mixed-citation><mixed-citation xml:lang="en">Taussig D., Montavont A., Isnard J. Invasive EEG explorations. Neurophysiol. Clin. 2015; 45 (1): 113-119. doi:10.1016/j.neucli.2014.11.006</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Fisch B. Spehlmann’s EEG Primer. Amsterdam: Elsevier, 1997. 642 p.</mixed-citation><mixed-citation xml:lang="en">Fisch B. Spehlmann’s EEG Primer. Amsterdam: Elsevier, 1997. 642 p.</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">Girvin J. History of epilepsy surgery. In: Operative Techniques in Epilepsy. Switzerland: Springer International Publishing, 2014. 307 p.</mixed-citation><mixed-citation xml:lang="en">Girvin J. History of epilepsy surgery. In: Operative Techniques in Epilepsy. Switzerland: Springer International Publishing, 2014. 307 p.</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">Olivier A., Boling W., Tanriverdi T. History of epilepsy surgery. In: Techniques in Epilepsy Surgery. United Kingdom: Cambridge University Press, 2012. 298 p.</mixed-citation><mixed-citation xml:lang="en">Olivier A., Boling W., Tanriverdi T. History of epilepsy surgery. In: Techniques in Epilepsy Surgery. United Kingdom: Cambridge University Press, 2012. 298 p.</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">Tyagun N.S., Mukhin E.Yu. Development of epilepsy surgery in the 2-nd half of XIX through mid-XX century. Russkiy zhurnal detskoy nevrologii = Russian Journal of Child Neurology. 2009; 4 (3): 41-46. [In Russian].</mixed-citation><mixed-citation xml:lang="en">Tyagun N.S., Mukhin E.Yu. Development of epilepsy surgery in the 2-nd half of XIX through mid-XX century. Russkiy zhurnal detskoy nevrologii = Russian Journal of Child Neurology. 2009; 4 (3): 41-46. [In Russian].</mixed-citation></citation-alternatives></ref><ref id="cit10"><label>10</label><citation-alternatives><mixed-citation xml:lang="ru">Reif P., Strzelczyk A., Rosenow F. The history of invasive EEG evaluation in epilepsy patients. Seizure. 2016; 41: 191-195. doi:10.1016/j.seizure.2016.04.006</mixed-citation><mixed-citation xml:lang="en">Reif P., Strzelczyk A., Rosenow F. The history of invasive EEG evaluation in epilepsy patients. Seizure. 2016; 41: 191-195. doi:10.1016/j.seizure.2016.04.006</mixed-citation></citation-alternatives></ref><ref id="cit11"><label>11</label><citation-alternatives><mixed-citation xml:lang="ru">Berger H. Uber das elektrenkephalogramm des menschen. Archiv fur Psychiatrie und Nervenk-rankheiten. 1929; 87: 527-570. doi: 10.1055/s-0028-1130334</mixed-citation><mixed-citation xml:lang="en">Berger H. About the human electroencephalogram. Archiv fur Psychiatrie und Nervenkrankheiten = Archives for Psychiatry and Nervous Diseases. 1929; 87: 527-570. [In German]. doi: 10.1055/s-0028-1130334</mixed-citation></citation-alternatives></ref><ref id="cit12"><label>12</label><citation-alternatives><mixed-citation xml:lang="ru">Almeida A., Martinez V., Feindel W. The first case of invasive EEG monitoring for the surgical treatment of epilepsy: Historical significance and context. Epilepsia. 2005; 46 (7): 1082-1085. doi:10.1111/j.1528-1167.2005.66404.x</mixed-citation><mixed-citation xml:lang="en">Almeida A., Martinez V., Feindel W. The first case of invasive EEG monitoring for the surgical treatment of epilepsy: Historical significance and context. Epilepsia. 2005; 46 (7): 1082-1085. doi:10.1111/j.1528-1167.2005.66404.x</mixed-citation></citation-alternatives></ref><ref id="cit13"><label>13</label><citation-alternatives><mixed-citation xml:lang="ru">Jasper H., Marsan C., Stoll J. Experimental studies of the subcortical projections of local cortical epileptiform discharge. Trans. Am. Neurol. Assoc. 1951; 56: 3-9.</mixed-citation><mixed-citation xml:lang="en">Jasper H., Marsan C., Stoll J. Experimental studies of the subcortical projections of local cortical epileptiform discharge. Trans. Am. Neurol. Assoc. 1951; 56: 3-9.</mixed-citation></citation-alternatives></ref><ref id="cit14"><label>14</label><citation-alternatives><mixed-citation xml:lang="ru">Lennox M., Brody B. Paroxysmal slow waves in the electro-encephalograms of patients with epilepsy and with subcortical lesions. J. Nerv. Ment. Dis. 1946; 104 (3): 237-248. doi:10.1097/00005053-194609000-00001</mixed-citation><mixed-citation xml:lang="en">Lennox M., Brody B. Paroxysmal slow waves in the electro-encephalograms of patients with epilepsy and with subcortical lesions. J. Nerv. Ment. Dis. 1946; 104 (3): 237-248. doi:10.1097/00005053-194609000-00001</mixed-citation></citation-alternatives></ref><ref id="cit15"><label>15</label><citation-alternatives><mixed-citation xml:lang="ru">Hayne R., Meyers R., Knott J. Characteristics of electrical activity of human corpus striatum and neighboring structures. J. Neurophysiol. 1949; 12 (3): 185-196. doi:10.1152/jn.1949.12.3.185</mixed-citation><mixed-citation xml:lang="en">Hayne R., Meyers R., Knott J. Characteristics of electrical activity of human corpus striatum and neighboring structures. J. Neurophysiol. 1949; 12 (3): 185-196. doi:10.1152/jn.1949.12.3.185</mixed-citation></citation-alternatives></ref><ref id="cit16"><label>16</label><citation-alternatives><mixed-citation xml:lang="ru">Talairach J., Bancaud J., Bonis A., Szikla G., Tournoux P. Functional stereotaxic exploration of epilepsy. Confin. Neurol. 1962; 22 (3-5): 328-331. doi:10.1159/000104378</mixed-citation><mixed-citation xml:lang="en">Talairach J., Bancaud J., Bonis A., Szikla G., Tournoux P. Functional stereotaxic exploration of epilepsy. Confin. Neurol. 1962; 22 (3-5): 328-331. doi:10.1159/000104378</mixed-citation></citation-alternatives></ref><ref id="cit17"><label>17</label><citation-alternatives><mixed-citation xml:lang="ru">Talairach J., Bancaud J. Lesion, «irritative» zone and epileptogenic focus. Confin. Neurol. 1966; 27 (1): 91-94. doi:10.1159/000103937</mixed-citation><mixed-citation xml:lang="en">Talairach J., Bancaud J. Lesion, «irritative» zone and epileptogenic focus. Confin. Neurol. 1966; 27 (1): 91-94. doi:10.1159/000103937</mixed-citation></citation-alternatives></ref><ref id="cit18"><label>18</label><citation-alternatives><mixed-citation xml:lang="ru">Northfield D. Experiment and neurological surgery. Br. Med. J. 1968; 4 (5629): 471-477. doi:10.1136/bmj.4.5629.471</mixed-citation><mixed-citation xml:lang="en">Northfield D. Experiment and neurological surgery. Br. Med. J. 1968; 4 (5629): 471-477. doi:10.1136/bmj.4.5629.471</mixed-citation></citation-alternatives></ref><ref id="cit19"><label>19</label><citation-alternatives><mixed-citation xml:lang="ru">Matias C., Sharan A., Wu C. Responsive neurostimulation for the treatment of epilepsy. Neurosurg. Clin. N. Am. 2019; 30 (2): 231-242. doi:10.1016/j.nec.2018.12.006</mixed-citation><mixed-citation xml:lang="en">Matias C., Sharan A., Wu C. Responsive neurostimulation for the treatment of epilepsy. Neurosurg. Clin. N. Am. 2019; 30 (2): 231-242. doi:10.1016/j.nec.2018.12.006</mixed-citation></citation-alternatives></ref><ref id="cit20"><label>20</label><citation-alternatives><mixed-citation xml:lang="ru">Sefcik R., Opie N., John S., Kellner C., Mocco J., Oxley T. The evolution of endovascular electroencephalography: historical perspective and future applications. Neurosurg. Focus. 2016; 40 (5): E7. doi:10.3171/2016.3.focus15635</mixed-citation><mixed-citation xml:lang="en">Sefcik R., Opie N., John S., Kellner C., Mocco J., Oxley T. The evolution of endovascular electroencephalography: historical perspective and future applications. Neurosurg. Focus. 2016; 40 (5): E7. doi:10.3171/2016.3.focus15635</mixed-citation></citation-alternatives></ref><ref id="cit21"><label>21</label><citation-alternatives><mixed-citation xml:lang="ru">Katz J., Abel T. Stereoelectroencephalography versus subdural electrodes for localization of the epileptogenic zone: what is the evidence? Neurotherapeutics. 2019; 16 (1): 59-66. doi: 10.1007/s13311-018-00703-2</mixed-citation><mixed-citation xml:lang="en">Katz J., Abel T. Stereoelectroencephalography versus subdural electrodes for localization of the epileptogenic zone: what is the evidence? Neurotherapeutics. 2019; 16 (1): 59-66. doi: 10.1007/s13311-018-00703-2</mixed-citation></citation-alternatives></ref><ref id="cit22"><label>22</label><citation-alternatives><mixed-citation xml:lang="ru">Zuev A.A., Golovteev A.L., Pedyash N.V., Ka-lybaeva N.A., Bronov O.Yu. Possibilities for surgical treatment of the pharmacoresistant form of epilepsy using robot-assisted implantation of deep electrodes for invasive stereoelectroencephalography. Neyrokhirurgi-ya = Neurosurgery. 2020; 22 (1): 12-20. [In Russian]. doi:10.17650/1683-3295-2020-22-1-12-20</mixed-citation><mixed-citation xml:lang="en">Zuev A.A., Golovteev A.L., Pedyash N.V., Ka-lybaeva N.A., Bronov O.Yu. Possibilities for surgical treatment of the pharmacoresistant form of epilepsy using robot-assisted implantation of deep electrodes for invasive stereoelectroencephalography. Neyrokhirurgi-ya = Neurosurgery. 2020; 22 (1): 12-20. [In Russian]. doi:10.17650/1683-3295-2020-22-1-12-20</mixed-citation></citation-alternatives></ref><ref id="cit23"><label>23</label><citation-alternatives><mixed-citation xml:lang="ru">Podkorytova I., Hoes K., Lega B. Stereo-encephalography versus subdural electrodes for seizure localization. Neurosurg. Clin. N. Am. 2016; 27 (1): 97-109. doi:10.1016/j.nec.2015.08.008</mixed-citation><mixed-citation xml:lang="en">Podkorytova I., Hoes K., Lega B. Stereo-encephalography versus subdural electrodes for seizure localization. Neurosurg. Clin. N. Am. 2016; 27 (1): 97-109. doi:10.1016/j.nec.2015.08.008</mixed-citation></citation-alternatives></ref><ref id="cit24"><label>24</label><citation-alternatives><mixed-citation xml:lang="ru">Minotti L., Montavont A., Scholly J., Ty-vaert L., Taussig D. Indications and limits of stereoelectroencephalography (SEEG). Neurophysiol. Clin. 2018; 48 (1): 15-24. doi:10.1016/j.neucli.2017.11.006</mixed-citation><mixed-citation xml:lang="en">Minotti L., Montavont A., Scholly J., Ty-vaert L., Taussig D. Indications and limits of stereoelectroencephalography (SEEG). Neurophysiol. Clin. 2018; 48 (1): 15-24. doi:10.1016/j.neucli.2017.11.006</mixed-citation></citation-alternatives></ref><ref id="cit25"><label>25</label><citation-alternatives><mixed-citation xml:lang="ru">Cossu M., Cardinale F., Castana L., Citterio A., Francione S., Tassi L., Benabid A., Russo G. Stereoelectroencephalography in the presurgical evaluation of focal epilepsy: a retrospective analysis of 215 procedures. Neurosurgery. 2005; 57 (4): 706-718. doi:10.1227/01.neu.0000176656.33523.1e</mixed-citation><mixed-citation xml:lang="en">Cossu M., Cardinale F., Castana L., Citterio A., Francione S., Tassi L., Benabid A., Russo G. Stereoelectroencephalography in the presurgical evaluation of focal epilepsy: a retrospective analysis of 215 procedures. Neurosurgery. 2005; 57 (4): 706-718. doi:10.1227/01.neu.0000176656.33523.1e</mixed-citation></citation-alternatives></ref><ref id="cit26"><label>26</label><citation-alternatives><mixed-citation xml:lang="ru">Serletis D., Bulacio J., Bingaman W., Najm I., Gonzalez-Martmez J. The stereotactic approach for mapping epileptic networks: a prospective study of 200 patients. J. Neurosurg. 2014; 121 (5): 1239-1246. doi:10.3171/2014.7.jns132306</mixed-citation><mixed-citation xml:lang="en">Serletis D., Bulacio J., Bingaman W., Najm I., Gonzalez-Martmez J. The stereotactic approach for mapping epileptic networks: a prospective study of 200 patients. J. Neurosurg. 2014; 121 (5): 1239-1246. doi:10.3171/2014.7.jns132306</mixed-citation></citation-alternatives></ref><ref id="cit27"><label>27</label><citation-alternatives><mixed-citation xml:lang="ru">Yang P., Zhang H., Pei J., Tian J., Lin Q., Mei Z., Zhong Z., Jia Y., Chen Z., Zheng Z. Intracranial electroencephalography with subdural and/or depth electrodes in children with epilepsy: Techniques, complications, and outcomes. Epilepsy Res. 2014; 108 (9): 1662-1670. doi:10.1016/j.eplepsyres.2014.08.011</mixed-citation><mixed-citation xml:lang="en">Yang P., Zhang H., Pei J., Tian J., Lin Q., Mei Z., Zhong Z., Jia Y., Chen Z., Zheng Z. Intracranial electroencephalography with subdural and/or depth electrodes in children with epilepsy: Techniques, complications, and outcomes. Epilepsy Res. 2014; 108 (9): 1662-1670. doi:10.1016/j.eplepsyres.2014.08.011</mixed-citation></citation-alternatives></ref><ref id="cit28"><label>28</label><citation-alternatives><mixed-citation xml:lang="ru">Vale F., Pollock G., Dionisio J., Benbadis S., Tatum W. Outcome and complications of chronically implanted subdural electrodes for the treatment of medically resistant epilepsy. Clin. Neurol. Neurosurg. 2013; 115 (7): 985-990. doi:10.1016/j.clineuro.2012.10.007</mixed-citation><mixed-citation xml:lang="en">Vale F., Pollock G., Dionisio J., Benbadis S., Tatum W. Outcome and complications of chronically implanted subdural electrodes for the treatment of medically resistant epilepsy. Clin. Neurol. Neurosurg. 2013; 115 (7): 985-990. doi:10.1016/j.clineuro.2012.10.007</mixed-citation></citation-alternatives></ref><ref id="cit29"><label>29</label><citation-alternatives><mixed-citation xml:lang="ru">Mullin J., Sexton D., Al-Omar S., Bingaman W., Gonzalez-Martinez J. Outcomes of subdural grid electrode monitoring in the stereoelectroencephalography era. World Neurosurg. 2016; 89: 255-258. doi:10.1016/j.wneu.2016.02.034</mixed-citation><mixed-citation xml:lang="en">Mullin J., Sexton D., Al-Omar S., Bingaman W., Gonzalez-Martinez J. Outcomes of subdural grid electrode monitoring in the stereoelectroencephalography era. World Neurosurg. 2016; 89: 255-258. doi:10.1016/j.wneu.2016.02.034</mixed-citation></citation-alternatives></ref><ref id="cit30"><label>30</label><citation-alternatives><mixed-citation xml:lang="ru">Sheth S., Aronson J., Shafi M., Phillips H., Velez-Ruiz N., Walcott B., Kwon C., Mian M., Dykstra A., Cole A., Eskandar E. Utility of foramen ovale electrodes in mesial temporal lobe epilepsy. Epilepsia. 2014; 55 (5): 713-724. doi:10.1111/epi.12571</mixed-citation><mixed-citation xml:lang="en">Sheth S., Aronson J., Shafi M., Phillips H., Velez-Ruiz N., Walcott B., Kwon C., Mian M., Dykstra A., Cole A., Eskandar E. Utility of foramen ovale electrodes in mesial temporal lobe epilepsy. Epilepsia. 2014; 55 (5): 713-724. doi:10.1111/epi.12571</mixed-citation></citation-alternatives></ref><ref id="cit31"><label>31</label><citation-alternatives><mixed-citation xml:lang="ru">Nilsson D., Fohlen M., Jalin C., Dorfmuller G., Bulteau C., Delalande O. Foramen ovale electrodes in the preoperative evaluation of temporal lobe epilepsy in children. Epilepsia. 2009; 50 (9): 2085-2096. doi:10.1111/j.1528-1167.2009.02135.x</mixed-citation><mixed-citation xml:lang="en">Nilsson D., Fohlen M., Jalin C., Dorfmuller G., Bulteau C., Delalande O. Foramen ovale electrodes in the preoperative evaluation of temporal lobe epilepsy in children. Epilepsia. 2009; 50 (9): 2085-2096. doi:10.1111/j.1528-1167.2009.02135.x</mixed-citation></citation-alternatives></ref><ref id="cit32"><label>32</label><citation-alternatives><mixed-citation xml:lang="ru">Velasco T., Sakamoto A., Alexandre V., Walz R., Dalmagro C., Bianchin M., Araujo D., Santos A., Leite J., Assirati J., Carlotti C. Foramen ovale electrodes can identify a focal seizure onset when surface eeg fails in mesial temporal lobe epilepsy. Epilepsia. 2006; 47 (8): 1300-1307. doi:10.1111/j.1528-1167.2006.00547.x</mixed-citation><mixed-citation xml:lang="en">Velasco T., Sakamoto A., Alexandre V., Walz R., Dalmagro C., Bianchin M., Araujo D., Santos A., Leite J., Assirati J., Carlotti C. Foramen ovale electrodes can identify a focal seizure onset when surface eeg fails in mesial temporal lobe epilepsy. Epilepsia. 2006; 47 (8): 1300-1307. doi:10.1111/j.1528-1167.2006.00547.x</mixed-citation></citation-alternatives></ref><ref id="cit33"><label>33</label><citation-alternatives><mixed-citation xml:lang="ru">Massot-Tarrus A., Steven D., McLachlan R., Mirsattari S., Diosy D., Parrent A., Blume W., Girvin J., Burneo J. Outcome of temporal lobe epilepsy surgery evaluated with bitemporal intracranial electrode recordings. Epilepsy Res. 2016; 127: 324-330. doi:10.1016/j.eplepsyres.2016.08.008</mixed-citation><mixed-citation xml:lang="en">Massot-Tarrus A., Steven D., McLachlan R., Mirsattari S., Diosy D., Parrent A., Blume W., Girvin J., Burneo J. Outcome of temporal lobe epilepsy surgery evaluated with bitemporal intracranial electrode recordings. Epilepsy Res. 2016; 127: 324-330. doi:10.1016/j.eplepsyres.2016.08.008</mixed-citation></citation-alternatives></ref><ref id="cit34"><label>34</label><citation-alternatives><mixed-citation xml:lang="ru">Valentin A., Hernando-Quintana N., Moles-Herbera J. Jimenez-Jimenez D., Mourente S., Malik I., Selway R., Alarcon G. Depth versus subdural temporal electrodes revisited: Impact on surgical outcome after resective surgery for epilepsy. Clin. Neurophysiol. 2017; 128 (3): 418-423. doi:10.1016/j.clinph.2016.12.018</mixed-citation><mixed-citation xml:lang="en">Valentin A., Hernando-Quintana N., Moles-Herbera J. Jimenez-Jimenez D., Mourente S., Malik I., Selway R., Alarcon G. Depth versus subdural temporal electrodes revisited: Impact on surgical outcome after resective surgery for epilepsy. Clin. Neurophysiol. 2017; 128 (3): 418-423. doi:10.1016/j.clinph.2016.12.018</mixed-citation></citation-alternatives></ref><ref id="cit35"><label>35</label><citation-alternatives><mixed-citation xml:lang="ru">Joswig H., Lau J., Abdallat M., Parrent A., MacDougall K., McLachlan R., Burneo J., Steven D. Stereoelectroencephalography versus subdural strip electrode implantations: feasibility, complications, and outcomes in 500 intracranial monitoring cases for drugresistant epilepsy. Neurosurgery. 2020; 87 (1): E23-E30. doi:10.1093/neuros/nyaa112</mixed-citation><mixed-citation xml:lang="en">Joswig H., Lau J., Abdallat M., Parrent A., MacDougall K., McLachlan R., Burneo J., Steven D. Stereoelectroencephalography versus subdural strip electrode implantations: feasibility, complications, and outcomes in 500 intracranial monitoring cases for drugresistant epilepsy. Neurosurgery. 2020; 87 (1): E23-E30. doi:10.1093/neuros/nyaa112</mixed-citation></citation-alternatives></ref><ref id="cit36"><label>36</label><citation-alternatives><mixed-citation xml:lang="ru">Yan H., Katz J., Anderson M., Mansouri A., Remick M., Ibrahim G., Abel T. Method of invasive monitoring in epilepsy surgery and seizure freedom and morbidity: A systematic review. Epilepsia. 2019; 60 (9): 1960-1972. doi:10.1111/epi.16315</mixed-citation><mixed-citation xml:lang="en">Yan H., Katz J., Anderson M., Mansouri A., Remick M., Ibrahim G., Abel T. Method of invasive monitoring in epilepsy surgery and seizure freedom and morbidity: A systematic review. Epilepsia. 2019; 60 (9): 1960-1972. doi:10.1111/epi.16315</mixed-citation></citation-alternatives></ref><ref id="cit37"><label>37</label><citation-alternatives><mixed-citation xml:lang="ru">Toth M., Papp K., Gede N., Farkas K., Kovacs S., Isnard J., Hagiwara K., Gyimesi C., Kuperczko D., Doczi T., Janszky J. Surgical outcomes related to invasive EEG monitoring with subdural grids or depth electrodes in adults: A systematic review and meta-analysis. Seizure. 2019; 70: 12-19. doi:10.1016/j.seizure.2019.06.022</mixed-citation><mixed-citation xml:lang="en">Toth M., Papp K., Gede N., Farkas K., Kovacs S., Isnard J., Hagiwara K., Gyimesi C., Kuperzko D., Doczi T., Janszky J. Surgical outcomes related to invasive EEG monitoring with subdural grids or depth electrodes in adults: A systematic review and meta-analysis. Seizure. 2019; 70: 12-19. doi:10.1016/j.seizure.2019.06.022</mixed-citation></citation-alternatives></ref><ref id="cit38"><label>38</label><citation-alternatives><mixed-citation xml:lang="ru">Park C., Hong S. High frequency oscillations in epilepsy: detection methods and considerations in clinical application. J. Epilepsy Res. 2019; 9 (1): 1-13. doi:10.14581/jer.19001</mixed-citation><mixed-citation xml:lang="en">Park C., Hong S. High frequency oscillations in epilepsy: detection methods and considerations in clinical application. J. Epilepsy Res. 2019; 9 (1): 1-13. doi:10.14581/jer.19001</mixed-citation></citation-alternatives></ref><ref id="cit39"><label>39</label><citation-alternatives><mixed-citation xml:lang="ru">Jacobs J., Wu J., Perucca P., Zelmann R., Mader M., Dubeau F., Mathern G., Schulze-Bonhage A., Gotman J. Removing high-frequency oscillations. Neurology. 2018; 91 (11): e1040-e1052. doi:10.1212/wnl.0000000000006158</mixed-citation><mixed-citation xml:lang="en">Jacobs J., Wu J., Perucca P., Zelmann R., Mader M., Dubeau F., Mathern G., Schulze-Bonhage A., Gotman J. Removing high-frequency oscillations. Neurology. 2018; 91 (11): e1040-e1052. doi:10.1212/wnl.0000000000006158</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
